Live monitoring¶
Before you record, it helps to see the incoming signal: check the levels, watch for clipping, and confirm a mode is where you expect. The web logger gives you two live views of the input: a monitor panel that stays with you on every stage, and a full-screen Live oscilloscope.
Both show whichever input is active: a browser soundcard, or a soundcard or NI device when the app is served locally. The Live stage computes its spectrum in the browser as the signal arrives.
The monitor panel¶
In the wide layout a Monitor panel sits at the foot of the dataset tray, so it stays visible on whichever stage you are on.
- When it is off it shows ▶ Start.
- When it is running it shows a small time trace, a level bar for each channel with a CLIP indicator, ⤢ to open the full Live stage (clicking the trace does the same), ▾ to collapse the panel body, and Stop.
It keeps running when you change stage. Start it once and it runs until you press Stop or close the tab.
On a narrow window the tray shrinks to a rail. The rail keeps a small strip with the level bars and a C clip indicator; click it to open the Live stage.
The Live stage¶
Open Live, or press ⤢ on the monitor, for the full oscilloscope. The Live card has these controls:
- Start Monitor, which becomes ⏸ Pause or ▶ Resume, and Stop, while it runs.
- display: Stacked puts each channel in its own lane. Auto Y fits the amplitude axis automatically, and is on by default.
- view time: how much time the trace shows. Choose 50, 100, 200 or 500 ms, or 1, 2, 5 or 10 s, or choose custom… and type a value from 0.02 s up to a limit set by memory (at most 30 s, less at high sample rates with many channels).
Four chips in the plot area show or hide the panes:
- T time: the oscilloscope trace.
- F freq: the live spectrum.
- L levels: the level bars and the CLIP indicator.
- P pause: freezes the display.
Live spectrum: FFT or PSD¶
- spectrum: FFT shows a per-frame amplitude spectrum. PSD shows an averaged Welch power spectral density, in dB/Hz or, on a linear axis, u²/Hz. Both use a Hann window.
- fft axes: magnitude in dB or lin, and frequency on a lin f or log f axis. A log axis opens three decades below its top.
- fft freq: Full shows DC to the Nyquist frequency. Range lets you type a minimum and maximum in hertz; a blank box means 0 or Nyquist.
In PSD mode two more controls appear:
- averages: 1× to 16× (1, 2, 4, 8 or 16) overlapping segments averaged. More averages give a steadier trace that responds more slowly.
- smoothing: off, low or high exponential smoothing across frames.
The Live spectrum is in the input's own units and is not calibrated. It is not the same quantity as the PSD on the Frequency stage.
Levels and clipping¶
Each level bar fills from green through amber to red as the peak rises. The CLIP indicator lights as soon as any channel's peak reaches 95 % of full scale, and stays lit until you click it or restart the monitor, so you don't miss a brief clip. If it lights, lower the input level, or on NI widen the voltage range, before recording.
Full scale depends on the input:
- an NI card: the input range you set in Setup, for example ±5 V, so a 3 V peak reads 60 % and does not light CLIP;
- a soundcard whose full scale is known: the full-scale voltage from its calibration; and
- the browser, or a soundcard with no known full scale: 1.0, the top of the converter's range.
Hover a bar to see its percentage, and its reading in volts where full scale is a voltage. Setup's input level readout (Acquisition and setup) reports the same peaks with advice.
Tips¶
- Set your levels on Live, then switch to Acquire to record. The monitor keeps running, so you can watch the levels while you set up.
- Catch gross problems here (clipping, a dead channel, the wrong device). It is much cheaper than re-recording. Coherence, on the TF stage, tells you about the measurement after the fact.
Next: Analysis views.