Acquisition and setup¶
You record in two stages. Setup is where you choose the device, sample rate, channels and duration, plus a trigger and, for NI hardware, the NI options. Acquire is where you press Log Data, with an optional pretrigger and output signal.
In the browser you record from your computer's soundcard, with a pretrigger and an output stimulus available. When the app is served locally you also reach NI-DAQ hardware and audio interfaces with calibrated volts. The table at the end of this page lists the differences.
Setup¶
Setup opens with the basic controls. Full ▾ reveals the advanced ones, and Basic hides them again. The defaults are 44.1 kHz, 1 channel and 2 s.
Basic controls¶
- input device: the device to record from. Default names the
device it resolves to when served locally, for example
Default — ESI U24 XL, so you know which hardware a capture will use. ↻ refreshes the list.- If a device appears under several host APIs (typically on Windows), only the recommended one is listed. Tick all backends to see them all.
- Served locally, pydvma remembers the device by name. If the list is renumbered while you work, it finds your device again and says so; if the device has been unplugged, the capture is refused instead of recording from a different input.
- sample rate: type any rate (
3000,3k,48 kHz) or pick one from the arrow list. Served locally the list holds the rates the device runs, plus lower standard rates that pydvma delivers by capturing faster and decimating; in the browser it holds standard rates. If the device can't run your rate itself, a note says so:captures at 48000 Hz, resampled to 3000 Hz. A rate above the device's maximum gets a warning and runs slower. - channels: the number of input channels, from 1 up to the device maximum. Not every input a device reports is a real one: a Scarlett 2i2 4th Gen advertises four, but 3 and 4 are a digital loopback of its own output mix. Setup warns you when you reach them.
- duration: the capture length in seconds. Type any value (
40,2.5,500ms,1m) or pick a preset (0.5, 1, 2, 5, 10, 30 or 60 s). - trigger: arm, the threshold, and on ch, the channel to
watch (shown when you have more than one channel). The threshold box
shows its unit. Where the input's full scale is known it is in volts,
with a hint such as
= 5 % of full scale. Otherwise it is a multiple of full scale (× full scale). Leave it blank for the default: 5 % of full scale in volts, or 0.05 × full scale. The group appears whenever the source can trigger. Arming here and on the Acquire card is the same switch. The rest of the trigger settings are under Full.
Browser: allow the microphone
A browser hides device names until you allow microphone access. Press Allow microphone access to see device names. Capture works without it, but you can't pick a named device.
Full controls¶
Full ▾ adds groups under the headings device, rates, levels, trigger and NI-DAQ. Read-only readouts are shown as plain text rather than as controls.
device (browser only)
- device capabilities: the channel count, sample-rate range and latency the browser reports for the input, once you have allowed microphone access.
- processing (off = raw measurement): echo cancel, noise suppress and auto gain. All three are off by default. Browsers turn them on for voice calls, and they change the signal, so leave them off for measurement.
- timing: a latency hint in milliseconds. Blank uses the browser's default.
rates
- digital low-pass: the oversample + decimate switch, off by default. See Digital low-pass.
- capture rate (served locally): strategy (auto, lowest or highest) and hardware rate, the rate the converter runs at, taken from the device's own list. auto is almost always right. The hardware rate box appears only when the device publishes a list of rates. See Capture rate and delivered rate.
levels
- What you see first depends on the interface (served locally). A characterised interface with a preamp shows input gain (for calibrated volts) and an input mode. A fixed-gain interface shows its full scale as a note. An interface pydvma has no profile for shows full scale (for calibrated volts), where you enter the measured full scale in volts peak. The full scale is what turns raw samples into volts, and pydvma can't read the preamp gain from the hardware. See Soundcard input gain and full scale.
- input level: the peak of each channel while the monitor is running,
in volts when the full scale is known and in dBFS otherwise, for example
ch0 0.5123 V pk. It ends with one line of advice: clipping — turn the input gain down, close to clipping — turn the gain down a little, very low — turn the input gain up, no signal — check the cable and the source, or levels look good. Start the monitor and check it before every capture. A clipped record looks plausible in the time trace but its spectrum is wrong.
trigger
- pretrigger context: how many samples to keep before the crossing. Blank uses 100.
- timeout: how many seconds to wait for a crossing. The default is 20. If it runs out, the capture happens anyway and is simply not aligned to a trigger.
Capture rate and delivered rate¶
The sample rate you choose is the rate the logged data ends up at.
The converter doesn't always run at that rate, because hardware only runs
the rates it has. Where the two differ, pydvma captures at a rate the
device does run and resamples to yours behind a linear-phase anti-alias
filter: passband to fs/2.56 and at least 96 dB of stopband at fs/2. The
filter has zero phase, so transfer functions and modal fits are
unaffected. Setup shows the real capture rate as a note, for example
captures at 44100 Hz, resampled to 8000 Hz.
The two rates differ in three cases:
- The device can't run your rate. A soundcard's lowest rate is well above 3 kHz, so a 3 kHz log is captured at the device's lowest suitable rate and decimated. pydvma does this itself with a known filter, rather than leaving it to the operating system's resampler, which can filter poorly. The sample-rate suggestions include these low targets for this reason.
- The digital low-pass is on, which captures above your rate on purpose (below).
- You set a hardware rate explicitly.
An NI delta-sigma module instead rounds an off-list rate to the nearest one it runs, and every axis uses the true rate. See NI hardware.
Digital low-pass¶
The digital low-pass switch runs the capture faster than your sample rate on purpose, then filters away the extra band as it resamples down. Your sample rate keeps its meaning: it is still the rate of the logged data. Two reasons to use it:
- Anti-aliasing. The NI USB-6003 and USB-6212 have no analogue anti-alias filter, so at a low sample rate anything above fs/2 folds into your band. Capturing fast and filtering digitally removes it, which gives these devices the anti-alias behaviour that a delta-sigma module such as the NI 9234 has in hardware.
- Lower noise. Rejecting out-of-band noise reduces broadband noise by about 10·log₁₀(oversample factor) dB.
How far above your rate it captures depends on the converter:
- An audio interface, or an NI delta-sigma module, filters in hardware. It captures at the lowest rate at or above 2.56 × fs (the resampler's passband runs to fs/2.56), because capturing faster rejects nothing extra and only makes more data.
- A converter with no anti-alias filter captures as fast as it can go.
strategy in capture rate overrides this: lowest or highest.
Served locally, the server does the whole chain. In the browser, the page records at the audio system's native rate and the analysis engine resamples afterwards. If there is no room to capture faster (your rate is already the lowest the device runs or, for a device with no published list of rates, its maximum is below 2 × fs), the log goes ahead unfiltered and says so.
NI-DAQ options¶
When the app is served locally with NI hardware, Full gains an NI-DAQ group: terminal configuration, NI voltage range (±V) for the input (in) and output (out), and IEPE off or IEPE 2 mA. These are hidden in the browser, which can't reach NI hardware. See NI-DAQ controls in Setup for what each does and how the devices differ.
IEPE applies to every channel
The IEPE switch powers every input channel. Don't use it with a non-IEPE sensor on another channel; see IEPE excitation for how to mix them.
Acquire¶
The Acquire stage records a capture.
- The settings chip summarises the pending capture:
fs · channels · duration · device · pretrigger, plus the output stimulus when it is on. Click the chip, or Edit, to go back to Setup. - Log Data records. While it records, a progress bar fills against
the capture duration next to a readout such as
12.4 / 30.0 s. An armed log that is waiting for its trigger shows a waiting state instead of a bar, because the clock starts only when the capture does. - Cancel stops a capture part-way. The button reads Cancelling… until the capture has stopped. Nothing is added to your data, and a message says the log was cancelled.
- When a capture finishes, it is added to the tray and the app moves to the Time stage.
Output stimulus¶
You can play an excitation signal while you record, which is what you need for a transfer-function measurement. In the output group:
- turn the switch on;
- choose the signal type: sweep (a linear chirp from f1 to f2), white (band-limited uniform noise) or gaussian (band-limited Gaussian noise);
- set amp (V) and the band f1 and f2 (the defaults are 0.3, 10 Hz and 500 Hz);
- leave match capture ticked to play the stimulus for the whole capture, or untick it and set dur (s) for a different length; and
- optionally choose the output device and out ch, when devices are listed (same as input is the default).
While the output is on, the Log Data button shows an OUT badge.
The amplitude depends on where you run:
- Served locally: volts, limited to the device's output rail. A frequency above half the sample rate is rejected with a message. With no output device chosen, the stimulus plays from the input device itself whenever it can (a USB interface plays from its own outputs), or from the system default output for a microphone-only input. Playing and recording on one device uses a single duplex stream.
- In the browser: a 0 to 1 peak level, because a browser has no calibrated output (the box is labelled V regardless). Choosing an output device needs a Chromium-based browser; others use the default output.
A soundcard has one clock for input and output. So when the stimulus plays from the device you are recording on, pydvma resamples it onto the capture rate, and a sweep still sweeps the same frequencies. Separate input and output devices keep their own clocks, and so does NI, subject to the device's output rate limit.
Pretrigger¶
To catch a transient such as an impact, turn on arm (in Setup's trigger group or on the Acquire card; it is one switch) and set the threshold. The capture starts when the absolute value of the trigger channel exceeds the threshold, and keeps the samples from before it. Once armed, the Acquire card also shows samples and timeout (s), the same values as in Setup's Full view.
While you wait, the card shows armed — waiting for trigger… with the threshold. Then it shows triggered — capturing, with the progress bar running, or trigger timeout — capturing buffered data if nothing crossed in time. The crossing sample sits at the pretrigger sample count you asked for.
The threshold is in volts when the full scale is known (the default is 5 % of it) and otherwise a fraction of full scale (0.05). In the browser it is always a fraction of full scale. The scripting equivalent is in the Python acquisition guide.
Calibration¶
Set each channel's sensitivity and unit from the tray, using cal on a dataset's card, not from Setup. See Calibration and units. Calibration is applied when data is displayed and fitted, so you can set or correct it after recording. What the stored samples mean is fixed when you record: NI hardware records volts directly, and a soundcard records volts only when its full scale is known, from the input gain or full scale in Setup's levels group.
What runs where¶
| Feature | In the browser | Served locally |
|---|---|---|
| Soundcard capture | ✅ | ✅ |
| NI-DAQ capture | — | ✅ |
| Browser audio-processing switches (off by default) | ✅ | — |
| Output stimulus | ✅ (0 to 1 amplitude) | ✅ (volts, limited to the rail) |
| Pretrigger | ✅ (threshold as a fraction of full scale) | ✅ (threshold in volts when full scale is known) |
| IEPE, terminal configuration, NI voltage range | — | ✅ (NI) |
| Digital low-pass | ✅ (the analysis engine resamples) | ✅ |
| Capture rate strategy and hardware rate | — | ✅ |
| Calibrated volts from a stated gain, a fixed-gain interface, or an entered full scale | — | ✅ |
From Python¶
Each Setup control has a MySettings argument, so a Python script can
set the same things. The rate the converter really ran at is recorded in
the capture's settings as lpf_capture_fs when it differs from fs.
| Setup control | MySettings argument |
|---|---|
| input device | device (a name), or device_driver and device_index |
| sample rate | fs |
| channels | channels |
| duration | stored_time |
| trigger: threshold, on ch, pretrigger context, timeout | pretrig_threshold, pretrig_channel, pretrig_samples (None means no pretrigger), pretrig_timeout |
| digital low-pass | lpf_on |
| strategy, hardware rate | oversample, capture_fs |
| input gain, input mode, full scale | input_gain_db, input_mode, VmaxSC |
| IEPE excitation, terminal configuration, NI voltage range | iepe_excit_current_A, NI_mode, VmaxNI, output_VmaxNI |
| output group | dvma.signal_generator(...), then dvma.log_data(settings, output=y) |
See the Python acquisition guide.